In order to create reliable quality on CR6 free requirement. FASCON has well training and investment on fasteners RoHS issue.
Now, FASCON has ability and facilities to detect CR6 free under customer's request.
Test standard : ISO 3613 Chromate conversion coatings on zinc, cadmium, aluminium-zinc alloys and zinc-aluminium alloys. Test methods |
|
|
|
| |
| |
|
1. Drip CR6+ test liquor on the fasteners surface. It shall appear any level purple color if there is CR6+ composition. The tested sample should be further verified by boiling-water-extraction method if the spot test result can not be confirmed.
2. To extract chromating layer through boiling water.Color will change to any level purple when drip with CR6+ test liquor if there is CR6+ composition in it.